Installation/Operation/MaintenanceTumble Dryers50 Pound (25 Kilogram) Capacity75 Pound (34 Kilogram) CapacityStarting Serial No. 0904004427Refer to Pa
Introduction Model IdentificationInformation in this manual is applicable to these models. Referto the machine serial plate for the model number.Gas S
Gas Steam/Thermal Oil Electric075 Series(34 Kg)CA075LCA075NCK075NCK075RCT075LCT075NCT075RCU075LCU075NCU075RDR75G2-BA075LDR75G2-BA075NDR75G2-BK075NDR75
D = Liquid Petroleum (L.P.) Gas, JapanE = ElectricF = Reduced Electric (Eco Line)L = L.P. GasN = Natural GasR = Reduced Gas, Natural Gas (Eco Line)S =
When calling or writing about your unit, PLEASE GIVE THEMODEL AND SERIAL NUMBERS. The model and serial num-bers are located on the serial plate. The s
Safety Information Explanation of Safety MessagesPrecautionary statements (“DANGER,” “WARNING,” and“CAUTION”), followed by specific instructions, are
• Always read and follow manufacturer’s instructions on pack-ages of laundry and cleaning aids. Follow all warnings or pre-cautions. To reduce the ris
Specifications and Dimensions Specifications and DimensionsRefer to machine serial plate for additional specifications.Specifications 050 Series 075 S
Specifications 050 Series 075 Series F75Motor: Horsepower [kW]Nonreversing 1/2 [0.373] 3/4 [0.560] Not ApplicableReversing Fan 1/3 [0.249] 1/3 [0.249]
Cabinet DimensionsTMB2422N_SVGEIHGFDKLJCBAModels A B C D E* F050 Series Gasand Electric30.75 in. [781mm]33.87 in. [860mm]48.25 in. [1226mm]76.625 in.
Models G H* I* J* K L050 SeriesSteam33 in. [838mm]7.1 in. [180mm]5.5 in. [140mm]6.53 in. [166mm ]29.5 in. [749mm]33.24 in. [844mm]075 Series Gasand El
Gas Connection LocationsTMB2239N_SVGBADiameter A B050/075 – 1/2 in. NPT 14.75 in. [375 mm] 65.75 in. [1670 mm]F75 – 3/4 in. NPTSpecifications and Dim
Electrical Connection LocationsTMB2240N_SVGBA1 2BA1. Gas and Steam2. ElectricA B3.25 in. [83 mm] 75.5 in. [1918 mm]NOTE: These figures are approx
Steam Connection LocationsTMB2425N_SVGBACD EDiameter ABC D E3/4 in. NPT 15.25 in. [387mm]79.23 in. [2013mm]7.5 in. [190 mm] 64.64 in. [1642mm]78.14 i
Installation Pre-Installation InspectionUpon delivery, visually inspect the crate, carton and parts for anyvisible shipping damage. If the crate, cart
TMB2242N_SVG43168725NOTE: Shaded areas indicate adjacent structure.1. 0 in. [0 mm] minimum, 0.5 in. [13 mm] recommended between machines for removal
Fire Suppression System (OptionalEquipment)WARNINGELECTRICAL SHOCK HAZARD. Electrical shock canresult in death or serious injury. If the water dispen
To connect the two hoses (supplied with tumble dryer), insertrubber washers (from literature pack) in water inlet hose cou-plings. Refer to Figure 5 .
TMB1999N_SVG1675431 21. Opening for Auxiliary Alarm Cable2. Fuse3. Auxiliary Alarm Fast-On Connection4. Test Button5. Light6. Reset Button
TMB2243N_SVG218765431. Trunnion Housing2. Junction/Contactor Box3. Vertical Trunnion Channel4. Cylinder Pulley5. Drive Guard6. Exhaust Thi
to access upper flange right guide lug assembly. Refer to Fig-ure 10 .3. Remove lint panel.IMPORTANT: Support door and hinge assembly se-curely to p
Installation must conform with local codes or, in the absence of local codes, with:In the U.S.A., installation must conform to the latest edition of t
TMB2496N_SVG67154321. Screw Cable Clamp2. Beginning Location of Door Switch Harness3. Original Switch Location4. Lint Panel Switch Harness5.
IMPORTANT: The electronic ignition system will at-tempt to light the gas by sparking for the “trial forignition” period. If gas does not ignite within
ModelsPrepurge Time(seconds)Trial for Ignition(seconds)Reset LockoutCondition By:Models starting 3/11/13through 12/31/13CE 1 10(attempts to ignite 3ti
the situations when the country of use or gas supply is differentthan that on the serial plate. If applicable, peel off the appropriatecountry sticker
GasTypeGasFamilyGroupGasDes-igna-tionSupplyPressurein. wc[mbar, kPa]ManifoldPressurein. wc[mbar,kPa]Capaci-ty/ModelOri-ficeDiam-eterinch[mm ]Ori-ficeP
GasTypeGasFami-ly GroupGasDe-scrip-tionGasDesig-nationWi Hi Ws Hs dWobbe In-dex(net)Heat-ingValue(net)Wobbe In-dex(gross)Heat-ingValue(gross)Densi-tyB
TMB2328N_SVG43211. Gas Shut-Off Valve (Ahead of pressure tap) (Shown inopen position) (Not Supplied)2. Pressure Tap3. Gas Shut-Off Valve (Shown
TMB2282N_SVG131211109876543211. Gas Valve2. Regulator Plate3. Burner Orifice4. Burner Tube Openings5. Burner6. Pressure Tap7. Spud Holde
Exhaust Requirements Exhaust RequirementsCAUTIONRisk of fire. A clothes dryer produces combustiblelint. Exhaust outdoors. Consult technical instruc-ti
Verify that old ducts are thoroughly cleaned out before installingnew tumble dryer(s).WARNINGImproperly sized or assembled ductwork causes ex-cess bac
WARNING• Installation of unit must be performed by a qualified installer.• Install tumble dryer according to manufacturer’s instructions and local cod
The exhaust duct must be designed so the static back pressuremeasured 12 inches [305 mm] from the exhaust outlet does notexceed the maximum allowable
One Manifold AssemblyTMB2403N_SVGLKJIHGFEDCBA121. Outlet duct diameter = largest duct diameter based on number of tumble dryers2. 45° typicalFigur
Two Manifold AssembliesTMB2018N_SVG12L LK KJ JIAAI1. Outlet duct diameter = combined largest duct diameter of both sides2. 45° typicalFigure 21Ref
Gas Requirements Gas RequirementsWARNINGTo reduce the risk of fire or explosion, DO NOT CON-NECT THE GAS LINE TO THE TUMBLE DRYER IFTHE GAS SERVICE IS
Non-CEand Non-AustralianModelsAustralianand Kore-an ModelsCE Mod-elsRecommend-ed11 in. w.c. 2.74 kPa 27.4 mbarMinimum 10 in. w.c. 2.49 kPa 24.9 mbarFo
Gas Supply Pipe Sizing and LoopingTMB2126N_SVG1 2 3 4 5 6 7 8 9M687453219 1011121. Gas furnace [120,000 Btu/hr. [127 Mj/hr., 35 kW]]2. Gas water
Low Pressure Gas Pipe SizesNOTE: Sizing calculations based on National Fuel GasCode.Gas Pipe Size Required for 1000 BTU Natural Gas (Standard Conditi
Gas Pipe Size Required for 1000 BTU Natural Gas (Standard Conditions) at Upstream Pressure— 7 ± 1.5 in-ches water column pressure [17.4 ± 4 mbar, 1.74
High Pressure Gas Pipe SizesNOTE: Sizing calculations based on National Fuel GasCode.IMPORTANT: A high pressure regulator is required.Gas Pipe Size R
Gas Pipe Size Required for 1000 BTU Natural Gas (Standard Conditions) at Upstream Pressure — 2 ± 0.4 PSI[138 ± 28 mbar, 13.7 ± 2.7 kPa]Gas Appli-ances
Restriction of hazardous substances (RoHS)The Table of Hazardous Substances/Elements and their Content As required by China’s Management Methods for
Model GasAltitude Burner OrificeNewRatefeet [me-ters] No.inches[mm] QuantityPartNumberBtu/hr.[Mj/hr.]*050 Series Natural Gas 2001-4000[610-1220]27 0.1
Model GasAltitude Burner OrificeNewRatefeet [me-ters] No.inches[mm] QuantityPartNumberBtu/hr.[Mj/hr.]*Eco Line 075SeriesNatural Gas50 Hz2001-4000[610-
Model GasAltitude Burner OrificeNewRatefeet [me-ters] No.inches[mm] QuantityPartNumberBtu/hr.[Mj/hr.]** Btu/hr. derate of 4% per 1000 feet [305 meters
Electrical Requirements Electrical RequirementsWARNING• To reduce the risk of electric shock, disconnectthis appliance from the power supply before at
Start Pulse RequirementsAll control types will consider a pulse valid if it is between 200and 1000 milliseconds in length, with a minimum of 200 milli
• A dedicated ground conduit (wire) must be connected be-tween the electrical service box ground bar and tumble dryerground screw.WARNINGTo reduce the
Ground and Terminal Block Locations for CE ModelsTMB2247N_SVG213451. Earth/Ground2. Junction Box3. Terminal Block4. Power Disconnect (Models T
Ferrite Ring InstallationGas and Steam Models with OM and RM Control Suffixes Only (Models Through 7/31/11)The ferrite ring provided in the literatur
Non-CE Models TMB2270N_SVG21 CE Models TMB2271N_SVG213 1. Ferrite Ring2. Junction Box3. Models Through 7/31/11Figure 28Electrical Requirements©
Electrical SpecificationsNOTE: Wire sizes were obtained from the CanadianElectrical Code for 75 C. wire and are intended for useas a guideline only.
Table of ContentsRestriction of hazardous substances (RoHS)... 5Introduction...
075 Series Gas and Steam ModelsSerial Plate RatingTerminal BlockConnections Re-quiredSerial Plate Amps Recommended CircuitNonre-versingRevers-ingBreak
050 and Classic Line 075 Series Electric ModelsSerial Plate RatingTerminal BlockConnections Re-quiredSerial Plate Amps Recommended CircuitNonre-versin
Steam Requirements Steam RequirementsNOTE: Steam valve and required adapter are located incylinder or lint compartment.NOTE: Machines require a consta
TMB2014N_SVG766351213121181094NOTE: Refer to Table 13 for sizing of steam lines. Piping must also be sized accordingly for length of runs andnumber of
Steam Pressure PSI [bar] Minimum Supply Pipe DiameterSteam Trap Size* Pounds Con-densate/Hour [Kilograms Con-densate/Hour]80-100 [5.3-6.9] 3/4 NPT 160
Single Drop TimerNOTE: The following information is for models with anSD control suffix only. Power-Up ModeWhen power is applied to the tumble dryer,
To reset the time, unplug the tumble dryer and set dipswitch 8 toON position. Restore power to the tumble dryer for 10 secondsand once again unplug tu
Heat TimePer CoinPulse (inminutes)Heat Switch Number1 2 3 4 5 622 ON OFF ON OFF ON OFF23 OFF ON ON OFF ON OFF24 ON ON ON OFF ON OFF25 OFF OFF OFF ON O
Heat TimePer CoinPulse (inminutes)Heat Switch Number1 2 3 4 5 648 ON ON ON ON OFF ON49 OFF OFF OFF OFF ON ON50 ON OFF OFF OFF ON ON51 OFF ON OFF OFF O
Cool Down Per Cycle (in minutes)Cool Down Switch Number4 ON ONModels Starting Serial No. 0909xxxxxCool DownPer Cycle (inminutes)Cool DownSwitch Num-be
Layout... 38Make-Up Air...
Operating Instructions Operating InstructionsWARNINGTo reduce the risk of fire:• DO NOT DRY articles containing foam rubber orsimilarly textured rubbe
3. Determine Control Type and Temperature Settinga. Refer to the various controls and follow the instructionsfor the appropriate control type.b.
TMB2150N_SVGFigure 36NOTE: One touch drying is available for repetitiveloads. If the START button is pressed while the ma-chine is in Idle Mode, when
Error CodesDisplay Definition Corrective ActionAF (Flashing) Bouncing Airflow Switch • Cycling power will not clear error. Start machine and al-low it
NOTE: All pads can be pressed in any sequencewithout damaging control or tumble dryer. To stopthe tumble dryer at any time, open the door or pressSTOP
TMB2338N_SVGFigure 452. Insert the coin(s) in the coin slot, or the card into the opening.TMB1492N_SVG TMB1963N_SVGFigure 463. Press START pad to
DRY576R_SVGFigure 48 Galaxy 600 ControlKB, KC, KK, KL, KW, KX, KY and KZ Control Suffixes1. Select HIGH, MED, LOW or DELICATES by pressing theapprop
TMB1438R_SVGFigure 49 LED OPL ControlEO and RE Control Suffixes1. Press the Up or Down keypad to change cycles.To customize a cycle, refer to the Pr
U Models TMB1371R_SVG Y Models TMB2370N_SVGSTARTSTOPBACK Figure 51C, D, and I Models TMB1375R_SVG Figure 52P Models Through 5/31/15 STARTBACKSTOPTMB23
UO and RU Control Suffixes1. Press the or keypad to change cycles. The centerhighlighted position is the selected cycle.To customize a cycle, ref
Operating Instructions...70Operating Instructions...
TemperatureDry-ingTimeCoolDownTimeLeft But-ton104°F [40°C] Varies 2 min.MiddleButton140°F [60°C ] Varies 2 min.RightButton176°F [80°C] Varies 2 min.Ta
DefaultPro-gramsDryTime(Min.)CoolTime(Min.)Temp.SetPointRe-versing3 – Misc-1 30 5 150ºF [66ºC] No4 – Misc-2 25 5 135ºF [57ºC] Yes5 – ExtraDry5 2 150ºF
9. Use the Up/Down arrows to change the counterclockwisetime within the range of 30-120 seconds.10. Press the REV button to save these settings and
Description of the OPL Control PanelTMB1956N_SVG68782134510111291. START. Starts or resumes the current program or cycle.2. STOP. Temporarily halt
Function OPL Coin4 Empty ON ON Always ON5 Empty ON ON Always ON6 Buzzer Timer ON ON 5 Sec=Off; Continuous=On7 Safety Tumble (OPL) or CoinCount/Pay (Co
Description of The Coin Control PanelTMB1955N_SVG9876543121. Clock Symbol. This symbol of a clock indicates that thetime in the display is counting
- LOW equal to 135ºF [57ºC]StopWhen in the Coin mode, the tumble dryer will stop if the tumbledryer door is opened while the tumble dryer is running.
Troubleshooting GuideControl does not start, green LED is off 1. 24 VAC present between 24V and ground on 70458701 only.If not, see machine schematic.
Ignition SequenceThe control begins the ignition sequence after prepurge by pow-ering the ignitor and opening the gas valve. The ignitor will re-main
enter Standby Mode. During Lockout Manual Reset, the Diag-nostic LED on the ignition control flashes red and orange, and theReset Light remains on unt
Removing Tumble Dryer from Service... 98Disposal of Unit...
Adjustments AdjustmentsWARNINGTo reduce the risk of electric shock, fire, explosion,serious injury or death:• Disconnect electric power to the tumble
T457I_SVG4142431. Proper Airflow2. Insufficient Airflow3. No Airflow4. Air Shutter Adjusting ScrewFigure 64 Airflow SwitchThe airflow switch i
TMB2105N_SVG11. Switch ActuatorFigure 65 Loading Door CatchThe door catch must be adjusted to have sufficient tension to holdloading door closed aga
Proper tension is when the drive belt can be depressed approxi-mately 0.5 inch [13 mm] by applying light thumb pressure [ap-proximately 5 pounds [0.35
Maintenance Daily1. Inspect the area surrounding tumble dryers, remove all com-bustible materials, including lint, before operating the ma-chines.2.
Bi-Annually1. Check mounting hardware for any loose nuts, bolts or screws.2. Check gas connections for leakage.3. Check for loose electrical co
dicated in Table 18 , the fire suppression system has failed themaintenance test. Refer to the Troubleshooting Manual.IMPORTANT: If the fire suppressi
Before You Call for ServiceWon’t Start Won’t Heat Clothes Not Dry Possible Reason – Corrective Actions• Insert correct coin(s) or valid card if applic
Removing Tumble Dryer from Service1. Turn off electrical supply external to machine.2. Turn off electrical disconnect on machine.3. Turn off gas
Disposal of UnitThis appliance is marked according to the European directive2002/96/EC on Waste Electrical and Electronic Equipment(WEEE).This symbol